Pengaruh Ketinggian Dan Redaman Dalam Meningkatkan Daya Keluaran Pada Panel Surya

Moh. Wahyu Aminullah, Iskandar Iskandar, Yuslan Basir

Abstract


One of the problems of laying solar panels and attenuation will affect the output power of the solar panels. Several other studies have been carried out with different heights and the addition of attenuation will increase the output power of solar panels. This research was conducted using experimental methods for 6 designs that have been planned. Design 1 solar panel without height and without attenuation, design 2 solar panels without height using attenuation, design 3 solar panels with a height of 10 m and without attenuation, design 4 solar panels with a height of 10 m and use attenuation, design 5 solar panels with a height of 75 m without using attenuation and design 6 solar panels with a height of 75 m and using attenuation. This study aims to determine the effect of changing the height of the solar panels and adding attenuation to see how much power the solar panels produce when they are sunny. Measurement of voltage (Voc) and current (Isc) was carried out for 5 days. The results showed that the highest average output power of solar panels was in design 6 of 45.16 W, while the lowest average output power of solar panels was in design 1 of 41.43 W. The output power of solar panels in design 6 is 8 .3% more than design 1

Keywords


Attenuation; Altitude; power pland; Solar Panel

Full Text:

PDF

References


A. C. A and H. SS, Energi baru dan Terbarukan Solusi Energi Masa Depan., Edisi Kedu. Jakarta: Listrik Indonesia, 2019.

A. Luque and S. Hegedus, Handbook of Photovoltaic Science and Engineering, Second Edi. John Willey & Sons, Inc., 2011.

J. Kafka and M. M, “A climatology of solar irradiance and its controls across the United States: Implications for solar panel orietation.,†Renew. Energy, vol. 135, pp. 897–907, 2019.

C. Zhang, C. Shen, Q. Yang, S. Wei, G. Lv, and C. Sun, “An investigation on the attenuation effect of air pollution on regional solar radiation,†Renew. Energy, vol. 161, pp. 570–578, 2020.

Y. Sianturi and C. M. Simbolon, “Pengukuran dan Analisa Data Radiasi Matahari di Stasiun Klimatologi Muaro Jambi,†Megasains, vol. 12, no. 1, pp. 40–47, 2021.

S. Turlan et al., “Solar cell research at an altitude of 3340 meters above sea level,†Mater. Today Proc., vol. 49, no. xxxx, pp. 1–3, 2021.

A. B. Awan, K. V. V. Chandra Mouli, and M. Zubair, “Performance enhancement of solar tower power plant: A multi-objective optimization approach,†Energy Convers. Manag., vol. 225, no. September, p. 113378, 2020.

H. K. Khwee, “Pengaruh Temperatur Terhadap Kapasitas Daya Panel Surya,†J. ELKHA2, vol. 5, no. 2, pp. 23–26, 13AD.

I. B. Ramadhani, Instalasi Listrik Pembangkit Tenaga Surya: Dos and Don’ts. Jakarta: Direktorat Jenderal energi Baru,terbarukan dan konservasi energi (DJ EBTKE) bekerja sama dengan Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ), 2018.

Rusman, “Pengaruh Variasi Beban Terhadap Efisiensi Solar Cell dengan Kapasitas 50 WP,†Turbo, vol. 4, no. 2, pp. 84–90, 2015.

N. Safitri and T. Rihayat, Buku Teknologi Photovoltaic, First Edit., no. July. Banda Aceh: YayasanPuga Aceh Riset, 2019.

R. Mayfield, Photovoltaic Design and Installation. John Willey & Sons, Inc., 2019.

M. B. Sari, Yulkifli, and Z. Kamus, “Sistem Pengukuran Intensitas dan Durasi Penyinaran Matahari Realtime PC berbasis LDR dan Motor Stepper,†J.Oto.Ktrl.Inst (J.Auto.Ctrl.Inst), vol. 7, no. 1, pp. 37–52, 2015.

K. Zhang, J. Yu, and Y. Ren, “Research on the size optimization of photovoltaic panels and integrated application with Chinese solar greenhouses,†Renew. Energy, vol. 182, pp. 536–551, 2022.




DOI: https://doi.org/10.33387/protk.v9i2.3294

Refbacks

  • There are currently no refbacks.


Copyright (c) 2022 Moh. Wahyu - Aminullah, Iskandar - -, Yuslan - Basir

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.



Editorial Office :
PROtek : Jurnal Ilmiah Teknik Elektro
Department of Electrical Engineering. Faculty of Engineering. Universitas Khairun.
Address: Jusuf Abdulrahman 53 Gambesi, Ternate City, Indonesia.
Email: protek@unkhair.ac.id, WhatsApp: +6282292852552
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.

View Stat Protek