ANALISIS UNSUR MINOR KATION DALAM SAMPEL AIR ALAM DENGAN MENGGUNAKAN TEKNIK KROMATOGRAFI ION

Muhammad Amin

Abstract


Tulisan ini berkaitan dengan studi banding mengenai kualitas air alam yang diperoleh dari berbagai lokasi di Ternate, Maluku Utara. Empat jenis air seperti air sungai, air sumur, air danau, dan air PDAM dievaluasi. Pada penelitian ini, teknik kromatografi ion digunakan sebagai metode analisis untuk menentukan kation anorganik (litium, natrium, amonium, kalium, kalsium, dan magnesium) yang terkandung dalam berbagai jenis air alam. Kombinasi Metrosep C2-150 sebagai kolom analitik dengan campuran eluen 4mM asam tartarat dan 0,75 mM asam dipikolinik digunakan dalam percobaan ini.

 

Kata Kunci: Kromatografi ion, air alam, kation anorganik


References


Small, H. 2004. Ion Chromatography: An account of its conception and early development. J. of Chem. Edu. 81: 1277–1284.

J. Weiss, 1995. Ion chromatography, 2nd ed., VCH, Weinheim.

Haddad P. R. and Jackson P. E., 1990. Ion Chromatography; Principles and Applications, Elsevier, Amsterdam, Netherlands.

Muhammad Amin, L. W. Lim, T. Takeuchi. 2005. Peak parking technique for the simultaneous determination of anions and cations. Anal. Bioanal. Chem. 381: 1426–1431.

Muhammad Amin, L. W. Lim, T. Takeuchi. 2006. Serial separation of cations and anions by ion chromatography using the peak parking technique and sulfosalicylic acid as the eluent. Anal. Bioanal. Chem., 384: 839–843.

Park, HM., Kim, YM., Lee, DW., Lee, SW. and Lee, KB. 2002. Ion chromatographic determination of inorganic anions in environmental samples of Korea. Analytical Sciences. 18: 343–346.

Jackson, PE. 2001. Determination of inorganic ions in drinking water by ion chromatography. TrAC Trends in Analytical Chemistry. 20: 320-329.

Muhammad Amin, L. W. Lim, T. Takeuchi. 2007. Tunable separation of anions and cations by column switching in ion chromatography. Talanta, 71: 1470–1475.

Muhammad Amin, L. W. Lim, T. Takeuchi. 2008. Determination of common inorganic anions and cations by non-suppressed ion chromatography with column switching. J. Chromatogr. A, 1182: 169–175




DOI: https://doi.org/10.33387/tk.v5i1.780

Refbacks

  • There are currently no refbacks.


Copyright (c) 2018 TECHNO: JURNAL PENELITIAN




-------------------------------------------------------------------------------------------------------------------------------------------------------------------

           

        

-------------------------------------------------------------------------------------------------------------------------------------------------------------------
TECHNO: Jurnal Penelitian
Published by: LPPM Universitas Khairun
Addres : Jalan Yusuf Abdurrahman Kampus II Unkhair, Kelurahan Gambesi, 97722 Kecamatan Kota Ternate Selatan, Provinsi Maluku Utara, Email: techno@unkhair.ac.id | URL: http://ejournal.unkhair.ac.id/index.php/Techno 

 


Techno Jurnal Penelitian is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

slot gacor slot gacor hari ini slot gacor 2025 demo slot pg slot gacor slot gacor