Protection System Coordination On 20 kV Distribution Network In Makassar City
DOI:
https://doi.org/10.33387/protk.v10i2.4204Abstract
This study is a quantitative study that aims to a) describe the coordination of protection systems under abnormal conditions in the distribution network and b) to determine the selectiveity of protection systems in isolating equipment in abnormal conditions of distribution networks. Data setting existing rele protection system obtained in PT. PLN (Persero) UP2D Makassar, the data is then processed, simulated, and analyzed using the ETAP 19.0.1 program. The series analyzed in this study is the distribution network PLN ULP Karebosi Paotere refiner with a channel length of 8,234 km, where sktm channel 0.844 km and SUTM 7,390 km, consisting of 33 distribution substations.  The results showed that the flow of short circuit disruption on Hatta buses was: 3-Phase by 3,887 kA, Line-to-Ground by 3,550 kA, Line-to-Line by 3,357 kA, and Line-to-Line-to-Ground by 3,831 kA. To achieve reliability and coordination of protection system equipment resetting rele on recloser Sabutung Set OCR 250 kA, TMS-TD OCR 0.08 s, moment OCR 3x, Sect. Paotere bridge OCR 200 kA, TMS-TD OCR 0.07 s, moment OCR Block, Sect. Hatta OCR 180 kA, TMS-TD OCR 0.05 s, moment OCR Block.Downloads
References
Lazuardi, Arya. 2018 "Perancangan Dan Sistem Pengendalian Switch Breaker Pada Jaringan Listrik Dengan Remote Control Via Sms". Skripsi. Depok : Universitas Indonesia
Ramadhan, R. (2014). Studi Koordinasi Sistem Pengaman Penyulang Trafo IV Di Gardu Induk Waru. Malang : Universitas Brawijaya.
Laidovica, & Budiono, (2018, Juli). Analisa Peningkatan Sistem Jtm 20 Kv Di Apj Surabaya Utara. Surabaya : Universitas 17 Agustus.
Hendra, Lazuardi, & Suparlan. (2015, Januari). Studi Penentuan Kapasitas Pemutus Tenaga Sisi 20 Kv Pada Gardu Induk Sekayu. Mikrotiga, hal16-21. Palembang : Universitas Sriwijaya.
Nugraha, Hari P. 2015 "Studi Koordinasi Sistem Proteksi Pada Jaringan Distribusi Pt Pln (Persero) Apj Gilimanuk Terhadap Pengaruh Penerapan SFCL (Superconductor Fault Current Limiter). Skripsi. Surabaya : Institut Teknologi Sepuluh Nopember.
Iriando, & Agung, (2019). Studi Koordinasi Sistem Proteksi Pada Transformator 20kv Di Jaringan Distribusi 20kv Penyulang Bandilan. Jurnal Teknik Elektro, 08(03).
Muflikha, S. (2021, Januari 19). Analisis Gangguan Hubung Singkat Pada Jaringan Distribusi Di Pt Pln (Persero) Up3 Makassar Utara Dengan Menggunakan Program Etap 12.6. Skripsi. Makassar : Universitas Negeri Makassar.
Downloads
Additional Files
Published
How to Cite
Issue
Section
License
Authors who publish with this journal agree to the following terms:
- The copyright of the accepted for publication articles shall be assigned to Protek : Jurnal Ilmiah Teknik Elektro as the publisher of the journal. The intended copyright includes the rights to publish articles in various forms (including reprints).
- Protek : Jurnal Ilmiah Teknik Elektro maintain the publishing rights of the published articles.
- Authors are permitted to republish or disseminate published articles by sharing the link/DOI of the article at Protek : Jurnal Ilmiah Teknik Elektro. Authors are allowed to use their articles for any legal purposes deemed necessary without written permission from Protek : Jurnal Ilmiah Teknik Elektro with an acknowledgment of initial publication to this journal.
Protek : Jurnal Ilmiah Teknik Elektro by Department of Electrical Engineering, Faculty of Engineering, Universitas Khairun
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.